3-D locking titanium miniplates in management of mandibular fracture; A prospective 64-67 clinical study


Author Details : Yadav S, Agarwal A, Singh S, Kumar S, Anand KR, Chhabra V

Volume : 3, Issue : 1, Year : 2015

Article Page : 64-67


Suggest article by email

Get Permission

Abstract

Purpose: The aim of this follow up clinical study was to evaluate the effectiveness of 2mm, 3-dimentional locking titanium miniplates.
Patients and Method: A prospective randomized clinical trial was carried out on 10 patients with mandibular fractures. The patients were evaluated for the operating time, clinical assessment of mobility after fixation, occlusion, adequacy of reduction on post-operative radiograph and any surgical complications. The statistical analysis was carried out in SPSS software.
Results: In 10 patients, 9(90%) were males and 1(10%) were females with a mean age of 28.75 years. Road traffic accident (RTA) was the etiological factor in 7(70%), inter-personal violence in 2 (20%) and fall in 1(10%) patient. The average intra-operative time was 40.10 min locking plates. This was found to be statistically significant when compared to the intra-operative time of non-locking plates in the literature. Bite force was measured in kilogram/cm2 using indigenously designed bite force measurement device. All the measurements were compared to the control group who did not sustain mandible fracture. At third month it was found that there was no significant difference in the bite between locking plates and control group. On examination satisfactory postoperative functional occlusion was found to be 100% in locking plates.
Conclusions: The results obtained suggest that 3-D locking plate/screw system fulfill the treatment goals of adequate reduction, fixation and stabilization of fracture of mandible. 3-D locking plating system adequately reduces the fracture without much need for adaptation and hence reduces the intra-operative time.

Keywords:
3-D locking miniplate, Mandibular fracture.


How to cite : Yadav S, Agarwal A, Singh S, Kumar S, Anand Kr, Chhabra V, 3-D locking titanium miniplates in management of mandibular fracture; A prospective 64-67 clinical study. J Dent Spec 2015;3(1):64-67


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







View Article

PDF File  


Copyright permission

Get article permission for commercial use

Downlaod

PDF File    






Article Access statistics

Viewed: 2980

PDF Downloaded: 473



Medical Abbreviation List