Effect of different contaminants on the shear bond strength of a newly introduced Self – etch adhesive system used with moisture protective barrier. – An in-vitro study


Author Details : Kumar P, Sharma R, Saroha K, Sharma P, Singh V

Volume : 3, Issue : 1, Year : 2015

Article Page : 54-59


Suggest article by email

Get Permission

Abstract

Aim and Objective: To assess and compare the shear bond strength of brackets bonded with two different self-adhesive systems with and without contamination (Water, Saliva and Blood) and to evaluate the effect of Salivatact on the shear bond strength obtained with Beauty Ortho Bond.
Material and Method: 15 premolars each (a total of 180) were bonded with Transbond XT plus, Beauty Ortho Bond and Beauty Ortho Bond with salivatact under various conditions i.e. dry, water, saliva and blood contamination. The shear bond strength and the ARI values were obtained and evaluated statistically.
Results: Transbond plus had the maximum bond strength in dry condition and when contaminated with water or saliva. The bond strength of Beauty Ortho Bond with and without salivatect was similar in dry condition and when contaminated with water or saliva.
The shear bond strength was lowest after the blood contamination in all the groups and highest for dry condition. Contamination with water and saliva resulted in similar strengths for all the groups. The bond strength achieved with all the three contaminants (water, saliva, blood) was similar when Salivatact was used.
Conclusion: Contamination decreases the bond strength for all the groups and this decrease is maximum in case of blood contamination. Bond strength of Transbond color change adhesive is higher than that of Beauty Ortho Bond under all conditions except when contaminated with blood using Salivatect. Beauty Ortho Bond using Salivatact had higher bond strength when contaminated with blood.

Keywords:
Bracket bond strength, Beauty ortho bond, Blood contamination.

 


How to cite : Kumar P, Sharma R, Saroha K, Sharma P, Singh V, Effect of different contaminants on the shear bond strength of a newly introduced Self – etch adhesive system used with moisture protective barrier. – An in-vitro study. J Dent Spec 2015;3(1):54-59


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







View Article

PDF File  


Copyright permission

Get article permission for commercial use

Downlaod

PDF File    






Article Access statistics

Viewed: 1412

PDF Downloaded: 325



Medical Abbreviation List