A comparative analysis of survival rate and shear bond strength of bondable molar tubes with two different mesh designs


Original Article

Author Details : Punia K, Shetty D*, Sharma P, Kumar P, Raza M

Volume : 7, Issue : 2, Year : 2019

Article Page : 84-88

https://doi.org/10.18231/j.jds.2019.021



Suggest article by email

Get Permission

Abstract

Objective: To evaluate and compare the shear bond strength (in vitro) and survival rate (in vivo) of molar tubes with conventional and modified mesh base designs.

Materials and Methods: Molar tubes of two different base design ie conventional (American Orthodontics) and modified base design (Ortho Organizers) were evaluated and compared for shear bond strength and survival. 20 molar tubes of each type were bonded on freshly extracted first permanent molars. Shear bond strength was tested using a Universal testing machine. 20 patients requiring fixed orthodontic treatment were selected. Molar tubes with two different base designs were placed on alternate sides in the four quadrants so that each arch had molar tubes of both types. Survival of the bonded tubes was evaluated monthly for a period of six months.

Results: Molar tubes having conventional mesh base design showed greater shear bond strength (10.49 Mpa) as compared to modified mesh base design (10.41 Mpa). The difference was found to be statistically significant (p=0.004). However, tubes with a modified mesh base (OO) showed a greater survival rate (95%) compared to those with conventional mesh base (85%).

Conclusion: Molar tubes with conventional mesh base design bonded with Transbond XT showed greater shear bond strength than molar tubes with modified mesh base design. Molar tubes with modified mesh base design showed a greater survival rate than molar tubes with conventional mesh base design.

Keywords: Shear bond strength, Molar tubes, Universal testing machine.


How to cite : Punia K, Shetty D, Sharma P, Kumar P, Raza M, A comparative analysis of survival rate and shear bond strength of bondable molar tubes with two different mesh designs. J Dent Spec 2019;7(2):84-88


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







View Article

PDF File  


Copyright permission

Get article permission for commercial use

Downlaod

PDF File    


Digital Object Identifier (DOI)

Article DOI

https://doi.org/10.18231/j.jds.2019.021


Article Metrics






Article Access statistics

Viewed: 1128

PDF Downloaded: 585